Failures when using C&B Metabond are highly unusual. Should this occur please check if
- the cement being mixed in the correct proportion
- the liquids expired or evaporated. Never forget to re-cap the containers immediately after use
If the problem persists consider priming with the C&B Metabond Dentin Activator